User Mode
Cha pte r B
Cha pte r B
9.5 Detector abnormality 9.5.1 Stop processing at detector abnormality (compulsory unload output) When a failure occurs with a detector that is needed to calculate the moment load ratio (load ratio) (error code Nos. of 1000s and 2000s), the automatic stop cannot be performed by the "re-stop condition." Therefore, in the AML cancel status at detector abnormality, all the stop functions are canceled. However, when the detector needed for stop function is working normally, the relevant automatic stop function is enabled (only the ones canceling is not allowed). The list of necessary detectors for automatic stop functions is shown in the table below. When a detector abnormality exists, compulsory unload is always performed due to the abnormality status but not by an operation. However, the slewing operation shall be permitted. Table 9.5.1 Relationship between detector abnormality and automatic stop function (including items that are not applicable depending on models) (1/3) Stop item Stop condition Do output control 100% lifting performance stop
E1001
AML status BM,S/T
E1002
AML communication line open × ×
E1003
E1004
AML reception line open ×
×
E1005
E1006
Transmitter abnormality ×
×
E1007
E1008
AML
transmission
data abnormality
×
×
JB
×
×
×
×
×
×
×
×
Anti-two-block stop
-
○
○
○
○
○
○
○
○
Backward stability stop
-
○
×
○
×
○
×
○
×
Boom upper limit stop
-
○
○
○
○
○
○
○
○
Boom lower limit stop
-
○
○
○
○
○
○
○
○
BM,S/T
○
○
○
○
○
○
○
○
Lifting height limit stop
JB
×
○
×
○
×
○
×
○
BM,S/T
○
○
○
○
○
○
○
○
JB
×
○
×
○
×
○
×
○
Jib tilt lower limit automatic stop
JB
×
○
×
○
×
○
×
○
Jib tilt upper limit automatic stop
JB
×
○
×
○
×
○
×
○
Main winch unwind stop
-
○
○
○
○
○
○
○
○
Auxiliary winch unwind stop
-
○
○
○
○
○
○
○
○
Automatic stop by no-insertion of jib fixing pin
-
×
○
×
○
×
○
×
○
Boom retraction automatic stop
-
×
○
×
○
×
○
×
○
Jib automatic pin stop
-
×
○
×
○
×
○
×
○
Jib set pin stop
-
×
○
×
○
×
○
×
○
PJ-JBS
×
○
×
○
×
○
×
○
-
×
○
×
○
×
○
×
○
-
×
○
×
○
×
○
×
○
Minimum elevating capacity stop
-
○
○
○
○
○
○
○
○
Automatic stop by pivot side no-insertion of jib connecting pin
-
×
○
×
○
×
○
×
○
Elevating cylinder stroke end stop
-
○
○
○
○
○
○
○
○
Elevation lower limit
-
○
○
○
○
○
○
○
○
Elevation upper limit
-
○
○
○
○
○
○
○
○
Load radius limit stop
Automatic stop by jib set abnormality Automatic stop by unlock the jib connecting pin Automatic stop by FLJ angle to ground 0°
BM: Boom, S/T: Single top, JB: Jib PJ: Power tilt jib, JBS: Jib set, FLJ: Full auto Luff. Jib
B - 56
W301-0471E