1 minute read
User Mode Chapter B Chapter B
6.1.1 100% lifting performance stop
When the moment load ratio (load ratio) exceeds 100%, the operation in the load ratio- increasing direction is stopped. However, for the main boom operation with jib, the automatic stop is performed when the moment load ratio (load ratio) becomes as follows:
Main boom with jib judgment: (1) and (2)
(1) Jib extension detection is in "extension" status (Di7: OFF).
(2) "Boom operation" is set with AML.
Code at stop: W0023
W0124 (For the main boom with jib)
Cancel: 100% stop cancel (Di6: ON)
Stop operation: (×: Stop operation)