Adjustment mode

Signal names and functions

- Signal name: External indicator lamp (90% to 100%, yellow)

When the moment load factor is 90% or more and less than 100%, the yellow external indicator lamp lights.

Output condition:

(1), (2) and (3)

(1): Moment load ratio is 90% or more and 100% or less.

(2) 100% stop cancel indication (Di6) is "Not canceled" status.

(3): Anti-two-block cancel indication (Di5) is "Not canceled" status.

15 Do15-

When in the boom operation with jib elected (during main operation with jib elected), the yellow external indicator lamp lights when the moment load ratio described below is reached.

16 Do16-

Output when condition is met: OFF output

- Signal name: External indicator lamp (100% or more, red) When the moment load ratio is 100% or more, the red external indicator lamp lights. Output condition:

(1) or (2) or (3)

(1): Load factor exceeds 100%.

(2) 100% stop cancel indication (Di6) is "Canceled" status.

(3): Anti-two-block cancel indication (Di5) is "Canceled" status.

When in the boom operation with jib elected (during main operation with jib elected), the red external indicator lamp lights when the moment load ratio described below is reached.

Output when condition is met: OFF output

2.1.8 CN6 connector (14-Pin)

CN6 connector

Pin No. Name

Signal names and functions

1 Ao1+ - Signal name: Slewing right proportional solenoid valve Drives the proportional reducing valve for right slewing.

2 Ao1-

3 Ao2+

- Signal name: Slewing right proportional solenoid valve COM (Output return terminal)

- Signal name: Slewing left proportional solenoid valve Drives the proportional reducing valve for left slewing.

4 Ao2- - Signal name: Slewing left proportional solenoid valve COM (Output return terminal)

5 Ao3+ - Signal name: Boom raising proportional solenoid valve Drives the proportional reducing valve for boom raising.

6 Ao3- - Signal name: Boom raising proportional solenoid valve COM (Output return terminal)

7 FG Frame ground

8 Ao4+ - Signal name: Boom lowering proportional solenoid valve Drives the proportional reducing valve for boom lowering.

9 Ao4- - Signal name: Boom lowering proportional solenoid valve COM (Output return terminal)

10 Ao5+ - Signal name: Slewing relief proportional solenoid valve Drives the proportional reducing valve for slewing relief.

11 Ao5- Signal name: Slewing relief proportional solenoid valve COM (Output return terminal)

12 AO6+ (Spare)

13 AO6- (Spare)

14 FG Frame ground