Chapter B
Main winch Aux. winch Boom telescoping Boom elevation Jib telescoping Jib tilt Slewing Jib mounting
Up Down Up Down Ext. Ret. Rse. Lwr. Ext. Ret. Rse. Lwr. Right Left Ext. Stw. × ×
6.1.4 Boom upper limit stop
Restriction is implemented to the operations exceeding the boom angle that is set with the area limit.
Code at stop: W0026
Cancel: 100% stop cancel (Di6: ON)
Stop operation: (×: Stop operation)
Main winch Aux. winch Boom telescoping Boom elevation Jib telescoping Jib tilt Slewing Jib mounting
Up Down Up Down Ext. Ret. Rse. Lwr. Ext. Ret. Rse. Lwr. Right Left Ext. Stw. ×
6.1.5 Boom lower limit stop
Restriction is implemented to the operations falling short of the boom angle that is set with the area limit.
Code at stop: W0027
Cancel: 100% stop cancel (Di6: ON)
Stop operation: (×: Stop operation)
Main winch Aux. winch Boom telescoping Boom elevation Jib telescoping Jib tilt Slewing Jib mounting Up Down Up Down Ext. Ret. Rse. Lwr. Ext. Ret. Rse. Lwr. Right Left Ext. Stw. ×
6.1.6 Lifting height limit stop
Restriction is implemented to the operations exceeding the lifting height that is set with the area limit.
Code at stop: W0028
Cancel: 100% stop cancel (Di6: ON)
Stop operation: (×: Stop operation)
Main winch Aux. winch Boom telescoping Boom elevation Jib telescoping Jib tilt Slewing Jib mounting Up Down Up Down Ext. Ret. Rse. Lwr. Ext. Ret. Rse. Lwr. Right Left Ext Stw. × × × ×