1 minute read
User Mode
6.1.7 Load radius limit stop
Restriction is implemented to the operations exceeding the load radius that is set with the area limit.
Code at stop: W0029
Cancel: 100% stop cancel (Di6: ON)
Stop operation: (×: Stop operation)
6.1.8 Elevation lower limit
As for the cranes whose moment detection is the differential pressure detection type, the moment detection becomes no longer possible when the elevating stroke end is reached. This function stops the elevation before the lowering stroke end is reached. However, to achieve the traveling configuration, when the slewing angle and boom length condition are satisfied, the lowering can be performed to the stroke end without a stop.
Stop condition: Boom angle ≤ Boom lowering stop angle A°, and in the crane status other than the one specified
Cancel: 100% stop cancel
Code at stop: W0054
Stop operation: (×: Stop operation)