Maintena nce Mode

Next Article
Adjustment mode

Adjustment mode

Do7 output ON trouble Although the Do7 output is ON, the output monitor incorrectly becomes OFF.

Cause: Signal line short to ground, board malfunction

Remedy: Perform inspection for the above possible cause.

Do8 output ON trouble Although the Do8 output is ON, the output monitor incorrectly becomes OFF.

E2216

Cause: Signal line short to ground, board malfunction

Remedy: Perform inspection for the above possible cause.

E2220

Do0 output stoppage The Do output power monitor voltage of the ESP controller is out of the normal range. Normal range: 18 V or more

Cause: Signal line short to ground, board malfunction of the ESP controller

Do1 output OFF trouble Although the Do1 output of the ESP controller is OFF, the output monitor incorrectly becomes ON.

E2221

Cause: Signal line short to ground, board malfunction of the ESP controller

Do2 output OFF trouble Although the Do2 output of the ESP controller is OFF, the output monitor incorrectly becomes ON.

E2222

Cause: Signal line short to ground, board malfunction of the ESP controller

Do3 output OFF trouble Although the Do3 output of the ESP controller is OFF, the output monitor incorrectly becomes ON.

E2223

Cause: Signal line short to ground, board malfunction of the ESP controller

Do4 output OFF trouble Although the Do4 output of the ESP controller is OFF, the output monitor incorrectly becomes ON.

E2224

Cause: Signal line short to ground, board malfunction of the ESP controller

Do5 output OFF trouble Although the Do5 output of the ESP controller is OFF, the output monitor incorrectly becomes ON.

E2225

Cause: Signal line short to ground, board malfunction of the ESP controller

Do6 output OFF trouble Although the Do6 output of the ESP controller is OFF, the output monitor incorrectly becomes ON.

E2226

Cause: Signal line short to ground, board malfunction of the ESP controller

Do7 output OFF trouble Although the Do7 output of the ESP controller is OFF, the output monitor incorrectly becomes ON.

E2227

Cause: Signal line short to ground, board malfunction of the ESP controller

E2228

This article is from: