Remote Control Valve Assembly and Disassembly Section
SH700-5
Remote Control Valve Removal and Installation of Operation Remote Control Valve Warning ・ Be sure to release hydraulic pressure before beginning work.
AL
Caution ・ Be sure to stop the engine before beginning work.
Items to prepare
TE RN
• Wrenches (19 mm, 22 mm) • Box wrench (10 mm) • Hexagon wrench (5 mm)
IN
• Phillips screwdriver • Marking pen • Caps
E
• Plugs • Rag
CO US N F E ID O E F N TS TI M AL GL : F O OR BA T L H
• Cleaning fluid
1. Removal of operation remote control valve (left side) [1] Roll up the boot (1) of the control lever and use the Phillips screwdriver or box wrench (10 mm) to remove the 2 bolts (2) of the console top cover.
[2] Use the Phillips screwdriver to remove the 2 screws (3), and then remove the handle of the tilt lever (4).
201
WSM-13-10-005EN 1