User Mode

Cha pte r B

Cha pte r B

6.1.2 Anti-two-block stop In the case of two-blocking, the operation in the hook block hoisting up direction is stopped. However, while the jib is being set, anti-two-block stop is not performed. Code at stop: W0024 “Stop due to overwinding (two-blocking)” Cancel: Two-blocking cancel (Di5: ON) Stop operation: (×: Stop operation) Main winch

Aux. winch

Boom telescoping

Boom elevation

Jib telescoping

Up

Up

Ext.

Rse.

Lwr.

Ext.

×

×

Down

×

Down

×

Ret.

×

Ret.

Jib tilt Rse.

Jib mounting

Slewing

Lwr.

Right

Left

Ext.

Stw.

×

6.1.3 Backward stability stop When the backward stability is lost, the operations that reduce the backward stability are stopped. Stop condition: During on-rubber operation, the boom angle becomes as follows: Model

Boom stop angle

Boom length

At suspension lock

At suspension free

9.80 m

73° or more (over-front area) 60° or more (over-side area)

16.64 m

73° or more (over-front area) 73° or more (over-side area)

GR-250N-3

9.37 to 23.46 m

Boom angle of 80° or more

GR-160N-3

GR-130N-1

GR-700N-1

Boom angle of 55° or more

Without stop

Code at stop: W0025 “Stopped due to backward stability” Cancel: None (Not allowed) Stop operation: (×: Stop operation) M winch Up

Down

A winch Up

Down

Boom telescoping

Boom elevation

Jib telescoping

Ext.

Ret.

Rse.

Ext.

×

×

Lwr.

B - 49

Ret.

Jib tilt Rse.

W301-0481E

Lwr.

Slewing Right

Left

Jib mounting Ext.

Stw.