1 minute read

Maintenance Mode

Next Article
Adjustment mode

Adjustment mode

C - 2 Individual Main Menu Function s

2.1 ROM ID check

In the maintenance main menu of Fig. 1.3.1, select "ID Code Check," and press the < > key to display the AML ID check screen shown in Fig. 2.1.1.

Pressing the < > key quits the menu, and the display returns to the maintenance main menu. Displayed items are listed below.

When the transmitter STM-D is connected, pressing the < > key or the < > key displays the connected device ID check screen shown in Fig. 2.1.2.

- ROM Code No.

- Crane Spec (Crane Specification code)

- Data ID

- Program ID

- Making date of data. (From left, year, month, day.)

- DCU2 Code No.

- VCU Code No.

- VCU Sub Rev.

2.2 Di check

Displays the status of digital input.

In the maintenance main menu of Fig. 1.3.1, select "Di Check," and press the < > key to display the Di check screen shown in Fig. 2.2.1.

Pressing the < > key (previous page) or the < > key (next page) changes the pages.

To go back to the maintenance main menu, press the < > key.

<Description of display contents>

Port

Di1 to Di28 : Input to AML

Ds11 to Ds18 : Input to serial port 1

Ds21 to Ds28 : Input to serial port 2

State

Close : Contact ON Open : Contact OFF

Reading method of Di signal (State)

Di signal “State” shows “Open” and “Close” of the each switch contact. However, Main and Aux. winch two-blocking detection switch (circuit) contacted with the series circuit. Therefore when either switch detects the overwound and the switch contact becomes “Open”, then, both contacts become “Open”. In a word, State of Di5 changes two signals at the same time. These functions are not provided in other Ai and Pi, etc.

2.3 Ai check

Displays the status of analog input.

In the maintenance main menu of Fig. 1.3.1, select "Ai Check," and press the < > key to display the Ai check screen shown in Fig. 2.3.1.

Pressing the < > key (previous page) or the < > key (next page) changes the pages.

To go back to the maintenance main menu, press the < > key.

<Description of display contents>

Port

Ai 1 to Ai 8 : Input to AML

As11 to As14 : Input from serial port 1 transmitter

As21 to As25 : Input from serial port 2 transmitter

Volt : Input terminal voltage

Value : Value of input voltage that is converted to the physical quantity

A/D : Value with which the input voltage is converted to digital value (0 to 5 V is converted to 0 to 4095.)

This article is from: