
1 minute read
User Mode
6.1.7 Load radius limit stop
Restriction is implemented to the operations exceeding the load radius that is set with the area limit.
Code at stop: W0029 “Stopped at lifting height limit restriction”
Cancel: 100% stop cancel (Di6: ON)
Stop operation: (×: Stop operation)
6.1.8 Automatic stop by unlock the jib fixing pin
When the power tilt jib is stowed, in order to protect the support, the tilt lowering operation is stopped in the case of side up jib, and the tilt raising operation is stopped in the case of midair extension jib.
For the side up jib, tilt lowering operation and jib extending operation are stopped in order to prevent the tension rod from buckling while the jib is being stowed.
For the midair extension jib, tilt raising operation and jib extending operation are stopped for the purpose of support protection.
Stop condition: (1) Jib connecting (lock) pin detection is in "inserted" status (Di7: ON).
(2) Jib lock (automatic) pin detection is in "inserted" status (Di4: ON).
Status that either of the above conditions (1) or (2) is met.
Code at stop: W0044 “Jib stowed condition”
Stop function cancel: None
Stop operation: (×: Stop operation)
With the midair extension jib (SACO jib), when the jib telescoping is selected without the jib connected.