2 minute read
Maintenance Mode
The data from the CMA connected with the CAN port cannot be acquired correctly. (Reception abnormality)
Cause: Bus connected with CAN is open or short. Device malfunction.
4.4.2 Detector abnormality or abnormal combination of detectors
Error code Error message Description
Boom length detector trouble
The detection value of boom length detector is out of the normal range.
Normal range: 5 to 95% (0.25 to 4.75 V)
E2003
Cause: Detector malfunction, signal line open/short circuit, board malfunction
Remedy: Perform inspection for the above possible cause. The status of any input from the detector can be checked using the “Ai check” function from the “Maintenance” menu.
Boom angle detector trouble
The detection value of boom angle detector is out of the normal range.
Normal range: 5 to 95% (0.25 to 4.75 V)
E2004
Cause: Detector malfunction, signal line open/short circuit, board malfunction
Remedy: Perform inspection for the above possible cause. The status of any input from the detector can be checked using the “Ai check” function from the “Maintenance” menu.
Jib length detector trouble
The detection value of jib length detector is out of the normal range.
Normal range: 5 to 95% (0.25 to 4.75 V)
E2005
Cause: Detector malfunction, signal line open/short circuit, board malfunction
Remedy: Perform inspection for the above possible cause. The status of any input from the detector can be checked using the “Ai check” function from the “Maintenance” menu.
Jib angle detector trouble
The detection value of jib angle detector is out of the normal range.
Normal range: 5 to 95% (0.25 to 4.75 V)
E2006
Cause: Detector malfunction, signal line open/short circuit, board malfunction
Remedy: Perform inspection for the above possible cause. The status of any input from the detector can be checked using the “Ai check” function from the “Maintenance” menu.
Jib angle detector trouble
E2007
The detection value of the jib angle detector (detection of angle to ground) is out of the normal range.
Normal range: 5 to 95% (0.25 to 4.75 V)
Cause: Detector malfunction, signal line open/short circuit, board malfunction
Right front outrigger length detector trouble
The detection value of front right outrigger length detector is out of the normal range.
Normal range: 5 to 95% (0.25 to 4.75 V)
E2009
Cause: Detector malfunction, signal line open/short circuit, board malfunction
Remedy: Perform inspection for the above possible cause. The status of any input from the detector can be checked using the “Ai check” function from the “Maintenance” menu.
Right rear outrigger length detector trouble
The detection value of rear right outrigger length detector is out of the normal range.
Normal range: 5 to 95% (0.25 to 4.75 V)
E2010
Cause: Detector malfunction, signal line open/short circuit, board malfunction
Remedy: Perform inspection for the above possible cause. The status of any input from the detector can be checked using the “Ai check” function from the “Maintenance” menu.
Left front outrigger length detector trouble
The detection value of front left outrigger length detector is out of the normal range.
Normal range: 5 to 95% (0.25 to 4.75 V)
E2011
Cause: Detector malfunction, signal line open/short circuit, board malfunction
Remedy: Perform inspection for the above possible cause. The status of any input from the detector can be checked using the “Ai check” function from the “Maintenance” menu.