1 minute read
Maintenance Mode
Do1 output OFF trouble
Although the Do1 output of the ESP controller is OFF, the output monitor incorrectly becomes ON.
Cause: Signal line short to ground, board malfunction of the ESP controller
Do2 output OFF trouble Although the Do2 output of the ESP controller is OFF, the output monitor incorrectly becomes ON.
E2222
Cause: Signal line short to ground, board malfunction of the ESP controller
Do3 output OFF trouble Although the Do3 output of the ESP controller is OFF, the output monitor incorrectly becomes ON.
E2223
Cause: Signal line short to ground, board malfunction of the ESP controller
Do4 output OFF trouble
Although the Do4 output of the ESP controller is OFF, the output monitor incorrectly becomes ON.
E2224
Cause: Signal line short to ground, board malfunction of the ESP controller
Do5 output OFF trouble Although the Do5 output of the ESP controller is OFF, the output monitor incorrectly becomes ON.
E2225
Cause: Signal line short to ground, board malfunction of the ESP controller
Do6 output OFF trouble Although the Do6 output of the ESP controller is OFF, the output monitor incorrectly becomes ON.
E2226
Cause: Signal line short to ground, board malfunction of the ESP controller
Do7 output OFF trouble
Although the Do7 output of the ESP controller is OFF, the output monitor incorrectly becomes ON.
E2227
Cause: Signal line short to ground, board malfunction of the ESP controller
Do8 output OFF trouble Although the Do8 output of the ESP controller is OFF, the output monitor incorrectly becomes ON.
E2228
Cause: Signal line short to ground, board malfunction of the ESP controller
Do1 output ON trouble Although the Do1 output of the ESP controller is ON, the output monitor incorrectly becomes OFF
E2229
Cause: Signal line short to ground, board malfunction of the ESP controller
Do2 output ON trouble Although the Do2 output of the ESP controller is ON, the output monitor incorrectly becomes OFF
E2230
Cause: Signal line short to ground, board malfunction of the ESP controller
Do3 output ON trouble Although the Do3 output of the ESP controller is ON, the output monitor incorrectly becomes OFF
E2231
Cause: Signal line short to ground, board malfunction of the ESP controller
Do4 output ON trouble Although the Do4 output of the ESP controller is ON, the output monitor incorrectly becomes OFF
E2232
Cause: Signal line short to ground, board malfunction of the ESP controller
E2233