User Mode

Cha pte r B

Cha pte r B

6.1.1 100% lifting performance stop When the moment load ratio exceeds 100%, the operation in the load ratio-increasing direction is stopped. However, for the main boom operation with jib, the automatic stop is performed when the moment load ratio becomes as follows: Output

Outrigger extension width

GR-130N-1

GR-160N-3

Maximum extension Middle extension 3

90% or more

Middle extension 2 Middle extension 1

GR-250N-3

GR-700N-1

88% or more

85% or more

83% or more

80% or more

78% or more

75% or more

Main boom with jib judgment: (1) and (2) (1) Jib extension detection is in "extension" status (Di7: OFF). (2) "Boom operation" is set with AML. Code at stop: W0023 “Stopped at 100% of crane performance” W0124 “Stopped at limit range of boom with jib” (For the main boom with jib) Cancel: 100% stop cancel (Di6: ON) Stop operation: (×: Stop operation) Main winch

Aux. winch

Boom telescoping

Boom elevation

Jib telescoping

Up

Up

Ext.

Rse.

Lwr.

Ext.

×

×

×

Down

Down

×

Ret.

×

Ret.

Jib tilt Rse.

Lwr.

Slewing Right

Left

Jib mounting Ext.

Stw.

×

Special note: The load ratio exceeds 100% when the boom raising stroke end is reached. Therefore, when the boom angle is A° or more, the automatic stop will not be performed for the boom lowering operation even when the load ratio is 100% or more. Model

GR-130N-1

GR-160N-3

GR-250N-3

GR-700N-1

Angle A°

80.9

81.4

83.3

83.2

B - 48

W301-0481E