Maintenance Mode
Cha pte r C
Cha pte r C
C-4 Error Code 4.1 Classification of error code The error code is displayed with the numerical value having four digits. The first digit (E1) indicates the error group. The following three-digit number indicates the individual code within the error group. E1
E2
E3
E4
Individual code Group code Group 0: Warning (Refer to Chapter B 3.2 Warning Code and Model Comparison Table) Group 1: Communication device (transmitter, etc.) error Group 2: Detector abnormality or abnormal combination of detectors Group 3: AML internal abnormality (system abnormality). When this abnormality occurs, the execution of control software is aborted. For about the error code table, refer to “4.4 Error code table.”
4.2 Error history The error codes from group 1 to 3 are stored in the AML together with the error occurrence time. (Note 1) The maximum of 50 error items are stored in the chronological order of occurrence. When the number of error items exceeds 50, the oldest record is deleted each time a new error occurs. (Note 1: The error code in group 3 is rarely stored.)
C - 48
W301-0481E