Electrical systems – 5000 Parameters Order number 229735-040
Date 2005-11-04
Valid from serial number 904519-
T-code 781
# 20 - Hour meter selection This parameter determines which hour meter mode to display during normal use.
Table 20: Hour meter parameter selection Value
Description
Display
1
Key time: Total time truck has been switched on.
2
Activity time: Combined time either pump or drive motor has been in operation. (Default display mode.)
3
Drive motor time: Total time drive motor has been in operation.
4
Pump motor time: Total time pump motor has been in operation.
5
Remaining time to next service. (Parameter #25 controls the initial value.) See “#25 - Service interval” on page 48 for more information.
# 21 - Battery size This parameter matches the discharge indication to the characteristics of the battery fitted.
Instructions for verifying parameter setting • Fully charge the battery. • Use the truck in its normal application until the battery indicator shows an empty battery (0% on the display). • Remove the battery from the truck and allow to rest for at least two hours. NB! No charging or discharging during this period. • Measure the battery acid’s specific density at room temperature. If the specific density is less than 1.15 g/cm3, the parameter value must be reduced. If the value significantly exceeds 1.15 g/cm3, the risk of damage to the battery is reduced. At the same time, the operating time of the truck is reduced. If a longer operating time is required, the parameter value can be increased by a maximum one step. • Each change must be accompanied by a new verification of the parameter setting. The acid’s specific density can vary depending on battery brand.
© TIEE SARL
Service Manual
7SM08F
11- 47