Table 21: Battery size parameter

WARNING!

Ensure you have set the parameter correctly. The battery may otherwise be irreparably damaged.

#22

- [S10] Type

This parameter is only used for other older truck models which use a mechanical [S10] switch. It is always set to 0 in this truck type.

#25

- Service interval

This parameter determines the time value in hours to the next service from 50 to 2000 hours in steps of 50 hours. Whenever this value is changed the timer is reset and will start counting activity time up to the set value. On reaching the set value caution code 29 (C29) will be shown on the display. The standard value for this parameter is 0, which means the timer is turned off.

#28 - Forks lift button selection

This parameter determines which buttons are used for forks lift function.

•Value 0 - No buttons active.

•Value 1 - A2:S19 & 20 operate forks / A2:S21 & 22 operate support arms (default).

•Value 2 - A2:S21 & 22 operate forks / A2:S19 & 20 operate support arms.

#39 - Log-in method & operator parameter access

This parameter determines which function will be used for log-in and whether or not the operator is allowed to adjust the operator parameter settings.

Table 22: Parameter #39 settings