Electrical systems – 5000 Parameters Order number 229735-040
Date 2005-11-04
Valid from serial number 904519-
T-code 781
• Repeat the step above until the PIN-code to be removed is displayed. • Press Horn button S18.
Parameter symbol flashes.
.
• Operate L1 to set the PIN-code value to “0” (zero). • Press Horn button S18.
Parameters symbol lights (stops flashing). The selected PIN-code has now been removed. To check whether a PIN-code will start the truck follow the procedure in Table 7, “Theory of operation,” on page 16 (Event 2 -Switch on (PIN code entry). Parameter #10 cannot be displayed without the CAN service key.
# 14 - Creep speed This parameter allows adjustment of the initial speed when the first Hall sensor is activated in the speed control [L1].
#15 - Non-configurable options Up to 10 so called sub-parameters are stored and accessed via parameter #15. These options are either switched ON or switched OFF and require no other adjustments. They are therefore called non-configurable options. The number of available options is dependant on the truck type. Consult table Parameter #15 Non-configurable options on page 46 for available options.
Setting Non-configurable options • Ensure the truck is in the parameter mode.
The parameters symbol lights. • Select parameter #15 using [L1]. The first sub-parameter will be displayed. Continued operation of the speed control L1 will display the next subparameter. Note also that only relevant sub-parameters will be displayed. After 1 second the value of the sub-parameter will be displayed. • Press horn button S18.
© TIEE SARL
Service Manual
7SM08F
11- 45