Lift mast – 7000 Main mast T-code 781
Valid from serial number 904519-
Date 2005-11-04
Order number 229735-040
13.1.2 Maintenance Mounting The maintenance schedule states that only a visual inspection of the mast mounting bolts (8) must be carried out and that they must not be tightened when they are checked. If the mast has to be replaced or if the bolts have become loose, new bolts and washers must be used. The tightening torque must be 150+/-15 Nm. Fig. 21 Bolt joints
Lubrication Lubricating the beam 1
2
13- 2
The inner sides of the beam flanges must be lubricated with TOYOTA part no. 223690 (Q8 Rembrandt EP2).
1
2
The inner sides of the beam rib must be lubricated with TOYOTA part no. 29586 (Gleitmo 805).
Service Manual
7SM08F
© TIEE SARL