Electrical systems – 5000 Parameters Order number 229735-040
Date 2005-11-04
Valid from serial number 904519-
T-code 781
Convention for configurable options • Each parameter can be designated to hold a particular base option. • Each designated option has up to 4 arguments associated with it. • Each argument holds a value which configures that option.
16 - 0 - 1
Parameter no. (range 16-19) Argument: #0 holds option designator (displayed for 2 s only) Argument value (range 0 - 63) 0= no base option is activated for this parameter 1 to 6 = Base option no. See separate tables)
OPTION ASSIGNATION
16 - 1- 1
Argument: #1, #2, #3 & #4 hold configurable values for the option Argument value (range depends on argument) Value depends on option and argument selected See separate table OPTION CONFIGURATION
Fig. 20 Configurable option laySetting Configurable options To activate a configurable option the base option must first be assigned to one of the parameters #16 to #19. This is achieved by setting argument #0 to the base option number. Once it is assigned, the option’s arguments must be configured. This is achieved by setting a value for arguments #1, #2, #3 and #4. • Ensure the truck is in parameter mode.
Parameters symbol lights. • Select parameter #16, #17, #18 or #19 using [L1]. Argument #0 will be displayed After 1 second the argument’s value will be displayed. A value of “0” indicates no option is assigned to this parameter, in which case continued operation of the speed control L1 will display the next parameter. • Press Horn button S18.
© TIEE SARL
Service Manual
7SM08F
11- 53