Model 6210 Maintenance Manual
Section 5. Troubleshooting Charger Troubleshooting
Charger Troubleshooting Symptom
Action
No indicator lights
Check AC power and connection to batteries.
Only blue AC light ON
Charger has AC power and is waiting for connection to batteries or CAN remote control commands. Battery voltage must rise over 0.2 volts per cell before charging begins.
Solid red Fault/Error/USB Indicator
Read fault code number on the charger display and refer to “Delta-Q Charger Codes” on page 6-38 for cause and corrective action.
Flashing amber Fault/Error/USB Indicator
Read fault code number on the charger display and refer to “Delta-Q Charger Codes” on page 6-38 for cause and corrective action.
Publication: 1146947, Revised: 12 Jan 2017