1 minute read

Model 6210 Maintenance Manual

36 Customer Option

Section 3.Systems Overview

Operator Display and Programming

0 to 20Parameter 36 supports alternative input options for the handle head rocker switch.

0 = None

1 = Lift-Limit with Bypass (if truck equipped)

2 = Secondary Horn

NOTE: Lift-Limit with bypass and horn are mutually exclusive.

37Not used

38Not used

39Access Code1 to 41Defines whether truck has a key switch or a keypad and what access level service personnel have to parameters.

1 = key switch only (no key pad)/operator parameters are open,

2 = key switch only (no keypad)/operator parameters are closed,

3 = keypad/operator parameters are open,

4 = keypad/operator parameters are closed. (When operator parameters are closed, Service Key is required to access operator parameters.)

40 Pendant Control

0 to 500 = Pendant Control Disabled

1 = 10% of maximum lowering speed empty

2 = 16% of maximum lowering speed empty

3 = 33% of maximum lowering speed empty

4 = 66% of maximum lowering speed empty

5 = Maximum lowering speed empty

41 Click-to-Creep0 to 4

1Enables creep travel with the tiller arm in the fully raised or lowered position.

0: Disable

1: Approximately 0.5 MPH

2: Approximately 1 MPH

3: Approximately 1.5 MPH

4: Approximately 2 MPH

Activate click-to-creep by clicking the speed control thumb wheel in either direction twice with the tiller in the brake position. “SLO” blinks on the display when in click-to-creep mode. Deactivate by clicking the speed control thumb wheel twice again. Also, the mode deactivates automatically after 10 seconds or immediately if the emergency reverse (belly button) switch is pushed.

65 to 255105Sets the maximum proportional valve raw data value. The larger the number, the higher the maximum allowed PWM to the proportional valve. This determines the maximum flow rate during a lower.

Publication: 1146947, Revised: 12 Jan 2017 3-17

Section 3.Systems Overview Model 6210 Maintenance Manual

0 to 200Sets the ramp rate for closing the proportional valve. The larger the number, the slower the valve closes.

to 25.20 24.84Changing this value will automatically change the “Full Volts” voltage. The Reset voltage will always be greater than the “Full Volts” voltage by at least 0.24 volts.

0 to 20Enables CAN communication for Delta-Q charger with charger profile selection.

0 = Disabled (default)

1 = Discover AGM Profile

2 = Trojan Wet Cell Profile

0 to 10Provides a separate profile with custom default settings for seven specific parameters (need Service Key to access).

Publication: 1146947, Revised: 12 Jan 2017

This article is from: