1 minute read
Model 6210 Maintenance Manual
Section 3.Systems Overview
Operator Display and Programming
3.8Prior to communication with the SWM, iPORT Initial Speed sets the maximum allowable truck speed.
NOTE: A 0 MPH setting disables truck functions.
NOTE: Raymond recommends that Init Speed be set to 0.5 (0.8 km/h) to prevent operation without being logged in.
3.8The Error Speed limit is activated when communication is interrupted and the truck comes to a stop. When communication is re-established, and throttle is brought back to neutral, normal operation is restored.
NOTE: Raymond recommends that Error Speed be set to 1.0 MPH (1.6 km/h).
20Hour Meter Selection 1 to 321 (A) = key time
2 (b) = activity time (drive, lift, or lower)
3 (c) = travel time
21Battery Type1 to 32Defines battery type for correct BSOC (battery state-of-charge) configuration.
1 = Industrial battery
2 = AGM battery
3 = Wet Cell battery and NEXSYS battery pack
100%75%Reset value for BSOC function. The displayed BSOC value must be below the selected level at key OFF before a fully charged battery will reset BSOC to 100% at key ON or reset to 100% when the voltage at key OFF is above the reset level. When battery BSOC level drops below this level, the truck will allow the BSOC to reset once Reset Voltage (Parameter 44) is reached.
200 msCreates a sequencing delay to allow for throttle engagement just before the brake is released. The Sequencing Delay timer is enabled when the throttle is engaged while the brake is applied. If the timer expires before the brake is released, error code ‘Hpd’ is generated by the VM.
Publication: 1146947, Revised: 12 Jan 2017 3-15