1 minute read
Model 6210 Maintenance Manual
CodeDescriptionSolution
Section 6.Messages and Codes
Delta-Q Charger Codes
E-0-2-9Cannot transmit on CAN bus•Check the physical CAN connector, electrical bus conditions and other CAN modules for correct functioning. For example, check termination resistance is approximately 60 ohms.
E-0-3-0CAN heartbeat timeout on battery module
•May be caused by a missing heartbeat message. Check the CAN Bus battery module for correct function.
This error will automatically clear once the condition has been corrected.
E-0-3-1The Vref for the ADC measurements has triggered an alarm
•Internal charger error. Remove AC and battery for minimum 30 seconds and retry charger.
•If the problem continues to exist, please contact the manufacturer of your vehicle or machine. This error will automatically clear once the condition has been corrected.
E-0-3-6Battery temperature sensor is missing or shorted
•Check if sensor is connected correctly
•The charger behavior when this fault occurs can be configured.
This error will automatically clear once the condition has been corrected.
E-0-3-7CANOpen reprogramming failed•Re-try CANOpen download or re-program using the USB.
This error will automatically clear once reprogramming has completed successfully.
E-0-3-8Fan will not turn•Check fan connections for loose wires.
•Check rotor is not locked, or fan is not obstructed. Inspect the fan and clear the blockage. This error will automatically clear once the condition has been corrected.
E-0-4-0Fan voltage pulled low•Make sure the fan is not stuck, sticking, or otherwise overloaded.
Publication: 1146947, Revised: 12 Jan 2017 6-45