Steering parameter settings Parameter
Display
Setting range
Mode
Meaning
STEER.POT. ZERO TEACH IN xx
0 - 255
Service
Steering angle potentiometer in forward position
STEER.POT. RIGHT TEACH IN xx
0 - 255
Service
Steering angle potentiometer setting for travelling around bends, right stop
STEER.POT. LEFT TEACH IN xx
0 - 255
Service
Steering angle potentiometer setting for travelling around bends, left stop
STEER RPM MIN
0..9
Service
Steering booster min. speed setting (standby)
STEER RPM MAX
0..9
Service
Steering booster max. speed setting (offset) Max. speed = Min. steer speed + max. steer speed
STEER POTI MIN
0..9
Service
Steering sensor analog supply setting at which point the min. steering speed set is increased (3,4 - 4,2V)
STEER POTI MAX
0..9
Service
Steering sensor analog supply setting at which point the max. steering speed set is increased (0,4 - 4,2V)
TURN/CONTROL
0..1
Service
Switches the steering angle monitor system on/off
Operating mode: The OPERATING MODE parameter can be used to select whether or not steering angle detection is installed in the truck. • Setting 0: No steering angle detection. No travel speed reduction when travelling around bends, Only fwd./rev. wheel position display • Setting 1: Steering angle detection installed. Travel speed reduction when travelling around bends, Wheel position display. • Default setting for OPERATING MODE = 1 If steering angle detection is not installed and the operating mode is set to 1, err 27 is generated.