1 minute read
Operating Program Setting
Operating Program Setting
Para meter
Display Setting range Mode
P00 OPERATING MODE 1...5 Service Operating Program Settings
Meaning
P01 ACCELERATION 0...9 Service Acceleration setting for the respective operating program.
P02 RELEASE BRAKE 0...9 Service Sets the brake pattern when the transmitter is quit (transmitter in zero position) for the respective operating program.
P03 INVERSION BRAKE
P04 PEDAL BRAKE
P27 REDUCTION BRAKE
P28 MAX. SPEED FW. P29 MAX. SPEED REV. P30 LIFT SPEED P31 LIFT RAMP UP 0...9 Service Sets the brake pattern for changing direction for the respective operating program. 0...9 Service Sets the brake current when the brake pedal is applied for the respective operating program. 0...9 Service Sets the brake current when the rated value is reduced for the respective operating program. 0...9 Service Maximum forward speed for the respective operating program 0...9 Service Maximum reverse speed for the respective operating program 0...9 Service Maximum lift speed for the respective operating program. 0...9 Service Ramp up for lift speed for the respective operating program
For trucks with the standard display the setting is made in operating program 3.