Lift parameter setting

Lift parameter setting

Para meter Display Setting range Mode Meaning

P01 TILT SPEED 0...9 Service Solo Pilot: Fwd./rev. tilt speed setting Mulitipilot: Max. fwd. tilt speed setting

P02 TILT SPEED BACKW. 0..9 Service Multi Pilot only: Max. rev. tilt speed setting

P03 ZH 1 SPEED 0...9 Service Solo Pilot: ZH1 speed setting Multi Pilot: Max. ZH1 speed setting

P05 ZH 2 SPEED 0...9 Service Solo Pilot: ZH2 speed setting Multi Pilot: Max. ZH2 speed setting

P13 LIFT POT ZERO TEACH IN xx 0-255 Service The left hand value gives the current potentiometer value applied, the right hand value gives the potentiometer value stored in the EPROM of the Canion at which point the controller starts to operate.

P14 LIFT POT MAX TEACH IN xx 0-255 Service

The left hand value gives the current potentiometer value applied, the right hand value gives the potentiometer value stored in the EPROM of the Canion at which point the controller is 100% stabilised. P15 PROP VALVE MIN 0...9 Service Minimum current for 3 way current control valve P16 PROP VALVE MAX 0...9 Service Maximum current for 3 way current control valve P21 ZH 3 SPEED 0...9 Service No function P27 AUX RAMP UP 0...9 Service Ramp down for lift function 0 = long ramp down P28 AUX RAMP DOWN 0...9 Service Ramp down for tilt, ZH1, ZH2 functions 0 = long ramp down P29 PWM RAMP UP 0...9 Service Ramp up for lowering proportional valve 0 = soft start for lowering P30 PWM RAMP DOWN 0...9 Service Ramp down for lowering proportional valve 0 = soft ramp down for lowering

Para meter Display Setting range Mode Meaning

P33 VALVE PULL VALUE 0...9 Service Pick up current with which the black/white valves are modulated.

P34 VALVE HOLD VALUE 0...9 Service Holding current with which the black/white valves are modulated.

P35 LOWER PWM MIN 0...9 Service Minimum PWM current for lowering valve 0 = :Low minimum current

P36 LOWER PWM MAX 0...9 Service Maximum PWM current for lowering valve 0 = :Low maximum current

P37 FORCE TO ZERO 0...3 Service See description below

P38 ZH1 + LIFTING 0...5 Service See description below