
1 minute read
Steering parameter settings
Steering parameter settings
Para meter Display Setting range Mode Meaning
STEER.POT. ZERO TEACH IN xx 0 - 255 Service Steering angle potentiometer in forward position
STEER.POT. RIGHT TEACH IN xx STEER.POT. LEFT TEACH IN xx 0 - 255 Service Steering angle potentiometer setting for travelling around bends, right stop
0 - 255 Service Steering angle potentiometer setting for travelling around bends, left stop
STEER RPM MIN
STEER RPM MAX
STEER POTI MIN
STEER POTI MAX
TURN/CONTROL 0..9 Service Steering booster min. speed setting (standby) 0..9 Service Steering booster max. speed setting (offset) Max. speed = Min. steer speed + max. steer speed 0..9 Service Steering sensor analog supply setting at which point the min. steering speed set is increased (3,4 - 4,2V) 0..9 Service Steering sensor analog supply setting at which point the max. steering speed set is increased (0,4 - 4,2V) 0..1 Service Switches the steering angle monitor system on/off
Operating mode:
The OPERATING MODE parameter can be used to select whether or not steering angle detection is installed in the truck. • Setting 0: No steering angle detection. No travel speed reduction when travelling around bends, Only fwd./rev. wheel position display • Setting 1: Steering angle detection installed. Travel speed reduction when travelling around bends, Wheel position display. • Default setting for OPERATING MODE = 1 If steering angle detection is not installed and the operating mode is set to 1, err 27 is generated.