Lift parameter setting Parameter
Display
Setting range
Mode
Meaning
P01
TILT SPEED
0...9
Service
Solo Pilot: Fwd./rev. tilt speed setting Mulitipilot: Max. fwd. tilt speed setting
P02
TILT SPEED BACKW.
0..9
Service
Multi Pilot only: Max. rev. tilt speed setting
P03
ZH 1 SPEED
0...9
Service
Solo Pilot: ZH1 speed setting Multi Pilot: Max. ZH1 speed setting
P05
ZH 2 SPEED
0...9
Service
Solo Pilot: ZH2 speed setting Multi Pilot: Max. ZH2 speed setting
P13
LIFT POT TEACH IN
ZERO xx
0-255
Service
The left hand value gives the current potentiometer value applied, the right hand value gives the potentiometer value stored in the EPROM of the Canion at which point the controller starts to operate.
P14
LIFT POT TEACH IN
MAX xx
0-255
Service
The left hand value gives the current potentiometer value applied, the right hand value gives the potentiometer value stored in the EPROM of the Canion at which point the controller is 100% stabilised.
P15
PROP VALVE MIN
0...9
Service
Minimum current for 3 way current control valve
P16
PROP VALVE MAX
0...9
Service
Maximum current for 3 way current control valve
P21
ZH 3 SPEED
0...9
Service
No function
P27
AUX RAMP UP
0...9
Service
Ramp down for lift function 0 = long ramp down
P28
AUX RAMP DOWN
0...9
Service
Ramp down for tilt, ZH1, ZH2 functions 0 = long ramp down
P29
PWM RAMP UP
0...9
Service
Ramp up for lowering proportional valve 0 = soft start for lowering
P30
PWM RAMP DOWN
0...9
Service
Ramp down for lowering proportional valve 0 = soft ramp down for lowering