I/O Data Display (Diagnostics) The data display has 19 display windows that can be selected with the MINUS and PLUS keys.
The process mapping of all I/O functions can be displayed in the ‘i/o data display’. This function is useful especially during commissioning and troubleshooting, as it allows for an exact prognosis on the condition of inputs and outputs. The menu item ‘i/o data display’ must be selected to activate the data display.
see “Special Functions Menu” chapter.
Quit data display One display window back One display window forward
The following displays can also be shown in succession: 1. Digital inputs 2. Analog inputs 3. PWM outputs 4. Analog outputs 5. Digital outputs 6. Counter inputs
Press ENTER to activate the data display function.
107