Liebherr Hydraulic excavator A 316 Litronic Operating instructions Manual - PDF DOWNLOAD

Page 74

Control, operation

Operating instructions

Operation

3.3.2.4

Throttle control

Fig. 3-33

Throttle control

The throttle control R75 permits continuous adjustment of the engine RPM over the full RPM range.

3.3.2.5

Engine overheating If the engine overheats, the indicator light H175 lights up and a warning signal (buzzer) sounds simultaneously. Shut down the Diesel engine immediately (see also the Deutz engine operating and maintenance manual).

Fig. 3-34

Diesel engine air intake

Note! To ensure optimum conditions for the engine, remove any ice and snow from the engine hood in the area of the cooling and combustion air intake before starting the Diesel engine.

3.3.2.6

Notes after starting the engine Danger! Danger of suffocation. When operating in closed spaces, run the engine only with sufficient ventilation. Open doors and windows to ensure sufficient supply of fresh air.

3 - 34