40.2 SERVICE BRAKE - REMOVAL AND INSTALLATION 40.2.1 PREPARATION AND SAFETY INSTRUCTIONS -

Stabilise the machine on level ground, fully retract the boom, place transmission control lever in neutral position. Ensure the engine is Shut OFF. Disconnect the battery .

40.2.2 PROCEDURE

!

NOTE Check the brakes at every 1000 hours of operation or on yearly basis.

12

1.

Uninstall and remove the brake cover plate (12) from the inside of the cabin.

8

7

2.

9

10

Disconnect the following Hoses from the Brake Master Cylinder (1): • Hose-Brake fluid tank to master cylinder (9). • Hose - Pump to brake master cylinder (7). • Hose-Brake master cylinder to return pipe (8). • Hose-Brake master cylinder to Front Axle (10).

13 14

15

3.

Uninstall the split pin(13) and the clevis pin(14). 4