Electrical System – 5000 Parameters T-code 677, 678, 679
Valid from serial number 723984-
Date 2005-10-28
Order number 222995-040
14.6.4 Parameter description Parameter 10 NOTE! The functionality of parameter #10 is set aside if the value of parameter #39 is set to 5,6,7 or 8. The PIN codes are managed using the socalled expanded keypad. See section “Expanded keypad - General” on page 50 for more detailed information.
Ten drivers can have their own PIN code to gain access to the truck. Each driver can set all driver parameters individually. On delivery the PIN code is set to 1 and this only applies for driver no. 1. Code 0 is not accepted as a solitary code. When you wish to start the truck enter your code and press the green button numbered 1. When you want to switch off the truck, press the red button numbered 0. When the CAN key is connected, you can start the truck by simply pressing the green button numbered 1. Switch off by pressing the red button numbered 0.
Parameter 14 Specifies the speed you will have when you reach the first speed sensor.
Parameter 15 - Non-configurable option See “Option parameters” on page 39.
Parameter 16 - Configurable option #1 See “Option parameters” on page 39.
Parameter 17 - Configurable option #2 See “Option parameters” on page 39.
Parameter 18 - Configurable option #3 See “Option parameters” on page 39.
Parameter 19 - Configurable option #4 See “Option parameters” on page 39.
14- 38
Service Manual
7PM18, 7PM20, 7PML20
© TIEE SARL