1 minute read
Electrical System – 5000
Error codes
•The 50 most recent error codes are stored. The latest error is displayed first. The display shows the error code first, followed by the time when the error occurred.
•The error codes are divided into two groups, C = caution and E = error.
•C codes are not stored. They are only cautions and remain lit in the display as long as the fault remains.
•If there is only one error registered in the memory, the other empty entry lines appear as follows: Error: E - - - and time: - - - - .
CodeC3
DescriptionTLS: Shock sensors registered values outside the limits
Possible error cause
A shock sensor has reported values that exceed the truck’s tolerance values. Driving may be too hard Check that the shock sensor’s limit values are correctly set. Check that the shock sensor is correctly positioned./The brake engages and stops the truck. The TLS reset command activates the truck
CodeC4
DescriptionTLS: Use of the truck has been blocked
Possible error cause Truck use can be “blocked” by a TLS command. / The truck cannot be used until a new TLS command cancels the blocking of the truck
CodeC19
DescriptionParameter caution. Displayed for 5 seconds.
Possible error cause The parameters have probably been changed. When changing/updating the program the parameters have automatically been changed to default values (only applies to old program versions). In later program versions the parameters are only changed if they are outside the values permitted by the new program.
Action 1.This means that the special parameters must be reset manually.
CodeC20
DescriptionSpeed control caution.
Possible error cause Problem with the speed control sensors. The toggle switch may have been activated when starting or there may be a fault on one of the sensors on the electronic card. (tiller arm head)
Action
1.Restart with the speed control in neutral position.
2.Replace the electronic card.
CodeC28
DescriptionEmergency switch caution
Possible error cause The emergency switch has been activated. No current to the travel regulator, input. A1/16.
Action
1.Check fuse F51.
2.Check the emergency switch.
3.Check the cables from the battery and the battery contacts.
4.If PTC resistor R1 is very hot, remove the battery contact and allow the resistor to cool. Restart.
CodeC29
DescriptionService warning
Possible error cause Time for service. The service counter has not been reset since the last service.