2 minute read
Electrical System – 5000 Parameters
Parameter no. (range 16-19)
Independent variable: #0 is the option designation
Independent variable value (range 0-63)
0= no option has been activated for this parameter
1 to 63 = Pre-programmed option number. See separate table.)
Setting The Optional Function
Independent variable: #1, #2, #3 & #4 contain the optional function valu
Independent variable value (the range depends on the function referred The value depends on the option and independent variable selected. See separate table
16 - 1- 1
Configuring The Optional Function
Changing configurable optional functions
In order to activate a configurable optional function, it must first be assigned a parameter from #16 to #19. This is done by changing independent variable #0 to the pre-programmed option number. Once this has been done, the independent variable for the option must be configured. This is done by changing the values for independent variables #1, #2, #3 and #4.
•Ensure the truck is in parameter mode.
The parameter symbol is lit.
•Select parameter #16, #17, #18 or #19 using [L1].
Independent variable #0 is displayed
The independent variable value is displayed after 1 second. The value “0” means that an optional function has not been assigned to this parameter, and the speed control L1 in this case displays the next parameter if you continue to activate it.
•Press the horn button S18.
The parameter symbol flashes.
•Enter the independent variable value #0 by repeatedly operating the speed control L1 in either direction. See Table 3:
•Press the S18 horn button once to confirm the new setting.
Electrical System – 5000 Parameters
The parameter symbol is lit (i.e. stops flashing).
•Select independent variable #1 by activating the speed control L1. Independent variable value #1 is displayed after 1 second.
•Press the horn button S18.
The parameter symbol flashes.
•Enter the independent variable value #1 by repeatedly operating the speed control L1 in either direction. See the list of optional functions in Table 3:
•Press the S18 horn button once to confirm the new setting.
The parameter symbol is lit (i.e. stops flashing).
Adjust independent variables #2, #3 and #4 in the same way as above.
•Switch off the truck by pressing on the keypad. The optional function is now activated.
•Check that the optional function works correctly before the truck is put back in operation.
Table 3: List of configurable optional functions
Independent variable #1
Independent variable #2
Independent variable #3
Independent variable #0 = 1: The option button controls the spider output 0:Spider 0 output 1
Independent variable #4 button 1-6Type of function:
1 output 2
2: :Digital output 3
3: :Digital output 4
Independent variable #0 = 2:Reduced running speed controlled by the spider’s digital input 0:Spider 0
1 input 1-80-12:reduced speed
(i.e. 40+5*arg3 e.g.
40+5*4=60%)
0:high-speed range 1:low-speed range 2: both ranges
Independent variable #0 = 3:Activate the spider output for specific movements
0:Spider 0 1:Spider 1 0:Digital output 1
1:Digital output 2
2: :Digital output 3
Select movements. See Table 4: position: 0: shines constantly
1: flashes 1 Hz
2: flashes 2 Hz