Tractor Storage Precautions Precautions to be taken for Tractor Storage Sr. No. 1
Every 15 days
Activity
Objective
a) First start the engine & allow it to idle for 2 to 3 minutes.
Lubrication to internal parts of the Engine.
b) Then run the tractor for 10 minutes from once place to another place at 1800 to 2000 rpm.
Lubrication to internal parts of the Transmission.
Charging of the battery.
Splashing of fuel from inside of the fuel tank.
Every 45 days
More than 45 days
2
Operate all electricals such as switches, flasher, lamps, horn.
To avoid malfunctioning due to oxidation of the contacts.
3
Drain the water inside the fuel tank using drain plug.
To avoid algae / rust formation & subsequent chocking of the fuel lines.
4
Raise the lift arms of hydraulics to their full raised position & lock the hydraulic system using the isolating valve on right hand side of control valve.
This raised position will fill the cylinder & protect it’s walls from corrosion.
5
Apply anti-oxidant spray on the battery / alternator / starter motor terminals.
To avoid oxidation of terminals.
6
Clean sheet metal & chassis with dry cloth.
To avoid accumulation dust which may result into detoriation of paint quality.
7
Keep the tractor with hand brake disengaged.
To avoid locking of the brakes
>
8
De-clutching - Place spacers between clutch pedal & foot plate to keep clutch plate free.
To avoid sticking of the clutch plate & subsequent damage.
>
9
Masking (with tape) of all the openings (Such as aircleaner, fuel tank cap, silencer, breathers of engine / brakes / transmission / hydraulic unit).
To avoid rusting due to moisture entry.
>
10
Disconnect battery terminals.
To avoid discharge of the battery.
>
11
If the tractor is intended for nonoperation for long time (more than a month) it is recommended to fill DEF to the max level as indicated by the DEF tank level indicator on the tank. This ensures SM filter is always immersed in the DEF liquid irrespective of any evaporation during storage. If the shutdown period (non operation) period is within 6 months, DEF quality to be checked before using the tractors. If the DEF quality is not ok, DEF to be replaced with right quality DEF for further usage of tractor. If the shutdown period is more than 6 months irrespective of DEF concentration, it is highly recommended to replace the DEF and perform SCR routine test at authorized Mahindra dealer.
To prevent crystal formation inside the Supply Module Filter due to DEF evaporation during long storage.
>
Indicates activity to be carried out at these intervals. > To be done whenever tractor is not in use for a long period of time i.e. more than 45 days. 138