Liebherr A 316 Litronic Industrie 716 Hydraulic Excavator Operating instructions Manual SN 28062 PDF

Page 96

Control, operation

Operating instructions

Working with the machine

Setting the stanchion cylinder shut-down: Danger! There is a risk that the equipment may come too close to the cab due to: – A work tool oscillating (e.g. grab) due to different dimensions of the work tool when opened and closed. – A delay in the shut-down process. Depending on the oil temperature and equipment type, the shut-off distance can be extended by up to 0.5 m. A minimum safety distance of at least 1.0 m to the danger object should be maintained.The machine operator is responsible for entering the correct settings! Take this into account when setting the stanchion cylinder shut-down.

Fig. 3-61

Cut-off point

For machines with a height adjustable cab, move the cab to its most forward projecting position (see Fig. 3-61). Move the equipment (boom) up as far as possible. Carefully retract industrial stanchion with appropriate attachment (grab etc.) until the required position is reached.

Fig. 3-62

Set the cut-off point

Release screws 1. Push limit switch 2 to the elongated hole until the outer edge 3 of the boom cuts the voltage field of the end switch. Tighten screws 1 again. Check stanchion cylinder shut-down.

3 - 62

MJFCIFSS

A 316 Litronic Industrie / 8720370


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.