_______________________________________________________ Operation Electrical starter enclosure The starter enclosure (Fig. 15) houses the primary electrical control components of the machine. The following switches and controls are located on the front of the enclosure: “MAN/OFF/AUTO”

The “MAN/OFF/AUTO” selector switch is used to set the mode of operation. Manual mode, “MAN” is used to bypass the outby conveyor sequence switch. When in manual mode, the outby conveyor belt does not need to be running. “AUTO” mode is used for normal operations.

“TRAM/OFF/CONV”

The “TRAM/OFF/CONV” selector switch is used to select tram or conveyor mode of operation. When in “OFF” mode, tram and conveyor functions are not active. “TRAM” mode is used when tramming the machine. When in tram mode, conveyor functions are not active. Conveyor mode, “CONV”, is used for normal operations. When in conveyor mode, tramming functions are not active.

“FWD CONV/OFF/REV CONV”

The “FWD CONV/OFF/REV CONV” selector switch is used to select the conveyor direction. If the switch is in “OFF” mode while the “MAN/ OFF/AUTO” switch is in “AUTO” mode, the conveyor will not run. Forward mode, “FWD CONV”, is used for normal operations.

“15A CB RESET”

The “15A CB RESET” pushbutton is used to reset the control circuit breaker.

“PICK BK STOP”

The “PICK BK STOP” pushbutton is used to stop the pick breaker motor.

“E-STOP”

The “E-STOP” button is used to trip the master control relay, thereby shutting down the machine. Power is still on the machine.

“ACKNOWLEDGE ALARMS”

The “ACKNOWLEDGE ALARMS” pushbutton is used to clear an alarm from the display panel after the condition that generated the alarm is corrected. This pushbutton is also used to engage the master control relay when starting the machine for the first time or after the panic switch/e-stop has been pressed.

“CONV START”

The “CONV START” pushbutton will initiate an automatic conveyor run cycle. The conveyor will run for the time duration preset. Note: The conveyor will not run until the breaker motor and hydraulic pump are running.

“START BREAKER”

The “START BREAKER” pushbutton is used to start the breaker motor. When the button is pushed, an alarm sounds for a preset amount of time. After the alarm sound, the breaker motor will start.

circuit breaker reset lever

The circuit breaker reset lever is used to reset the main circuit breaker when it has tripped. To reset the breaker, push the handle down, past “OFF”, to “RESET” and then back up to “ON”.

______________________________________________________________ A6474X391 REV 4 5.11


Turn static files into dynamic content formats.

Create a flipbook

Articles inside

Roof cylinder ................................................................ 5

3min
pages 209-211

Tilt cylinder ................................................................... 5

1min
pages 214-215

Tailpiece installation ..................................................... 5

2min
pages 205-208

Breaker bit removal ...................................................... 5

1min
page 204

Conveyor drive unit ...................................................... 5

2min
pages 201-203

Breaker shaft only ........................................................ 5

10min
pages 192-200

Breaker power unit only ................................................ 5

3min
pages 189-191

Breaker shaft and breaker power unit ......................... 5

5min
pages 183-188

Crawler assembly ........................................................ 5

8min
pages 174-182

Pressure limiter adjustment .......................................... 5

1min
page 149

Head shaft sprockets ................................................... 5

4min
pages 154-156

Crawler track ............................................................... 5

3min
pages 171-173

Conveyor chain ........................................................... 5

7min
pages 163-170

Main relief pressure………………………………………5

1min
page 148

Crawler track adjustment .............................................. 5

2min
pages 140-141

Main pump adjustments ................................................ 5

2min
pages 146-147

Conveyor chain adjustment .......................................... 5

1min
pages 138-139

Inspection of the fire suppression system .......................... 5

1min
pages 130-131

Instructions on the adjustment procedures ....................... 5

1min
pages 136-137

Procedure to set Amplifier Card ......................................... 5

2min
pages 134-135

Major hydraulic components .......................................... 5

4min
pages 88-89

Every 6 months ............................................................. 5

2min
pages 125-127

Every 3 months ............................................................. 5

1min
page 122

Primary hydraulic circuit ................................................ 5

1min
pages 90-92

Starter enclosure ........................................................... 5

4min
pages 82-85

Electrical system ................................................................. 5

3min
pages 79-81

Tramming the machine ....................................................... 5

1min
page 73

Conveyor ............................................................................ 5

3min
pages 74-75

Control system operating parameters ................................ 5

2min
pages 76-78

Shutdown procedure .......................................................... 5

1min
page 72

“MANUAL” mode starting procedure .................................. 5

1min
page 71

“AUTO” mode starting procedure ....................................... 5

1min
page 70

Starter enclosure ........................................................... 5

3min
pages 59-61

Towing the feeder breaker ................................................. 4

1min
pages 62-63

Safety features................................................................. 4

2min
page 54

Infrared pump motor controls ........................................ 5

1min
page 65

Radio remote ................................................................. 5

3min
pages 66-69

Dust suppression system .............................................. 5

1min
page 64

Function pressure gauge ................................................. 5

1min
page 56
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.