Case WX120 Wheeled Excavator Operator's Manual Cre 6-30060 GB - PDF DOWNLOAD

Page 288

OPTIONS

BIODEGRADABLE HYDRAULIC OIL Specifications • Recommended oil PANOLIN AG. - HLP SYNTH 46. Operating range • Ambient temperature: -20 °C a 40 °C. • Oil temperature in the reservoir -20 °C to 95 °C.

Instructions for use IMPORTANT: Biodegradable hydraulic oil must not be mixed with mineral hydraulic oil.

Oil change

Oil sampling for analysis

Every 2000 hours

Every 500 hours

• Oil samples to be analysed should be taken every 500 hours of operation using the sampling kit and related instructions supplied by the Dealer. • The samples should be sent by the Customer to PANOLIN AG., that will carry out necessary analyses. The Dealer will then inform the Customer when oil characteristics are no longer suitable for use.

IMPORTANT: If special tools (hydraulic breaker, etc.) are used, oil sampling for analysis should be done every 250 hours.

S0089

27401 6-30060 GB

IMPORTANT: Oil should be changed if the Dealer informs the Customer that oil is outside operating limits. Failure to observe this measure will invalidate the warranty and may cause damages to the machine. Refer to the hydraulic system oil replacement procedure detailed in “MAINTENANCE AFTER 2500 HOURS OF OPERATION”, in the paragraph “HYDRAULIC SYSTEM OIL”.

Study SAFETY RULES in the front of this manual thoroughly for the protection of machine and safety of personnel