1 minute read
Fuel tank (draining condensation
FUEL TANK (Draining condensation)
WARNING
In the presence of inflammable vapours, extinguish all smoking materials and naked lights before checking fuel level, refuelling the machine, replacing the filters, or removing the condensation drain plug.
• Park the machine on a level surface, with the upperstructure turned to 90° to make access easier.
• Lower the bucket to the ground.
• Switch off the auto-idle, fully turn the engine speed manual control anticlockwise, stop the engine, remove the starter key and move the safety lever into the locked position (LOCK).
F5590
NOTE: A plug is installed on the drain cock to prevent introduction of dirt and as a protection against vandalism.
• Drain the tank of impurities (water and deposits) deposited on the tank bottom.
• To do this, remove the plug (1) from the drain cock (2) which is located under the upperstructure, at the tank. Slowly open the cock and let condensation and deposits drain into a a suitable container until only clean fuel comes out.
NOTE: When the temperature is above 0°C draining can be done before engine start-up. When working with temperatures below 0°C, the tank should be drained at the end of work, after engine shut-down, as water might freeze and not drain properly.
• After draining, close the cock and reinstall the plug.
Handle and dispose of the water mixed with fuel oil according to current legislation. Use only authorised disposal procedures. If in doubt, contact authorities concerned. 2
1
F5883 27401 6-30060 GB