OPTIONS
HYDRAULIC OIL AND FILTER ELEMENT SERVICE INTERVAL When the hydraulic breaker is used, the excavator is subjected to working conditions more critical than usual, that speed up hydraulic oil deterioration and contamination. To prevent damages to the excavator hydraulic system, breaker, carefully respect service intervals detailed in this Manual. In particular, replace hydraulic oil and filter element according to the instructions below:
(*) IMPORTANT: Change intervals shown should be applied if the machine is used 100% of the time equipped with the hydraulic breaker. In case of lower time percentage of breaker use, hydraulic oil and filter element change intervals may vary accordingly to the following diagram.
Change interval (hrs)
Component to be replaced
Machine equipped with hydraulic breaker
Machine installed with bucket
Hydraulic oil (**)
600 (*)
2500
Filter element
100 (*)
500 F5696i
Hydraulic breaker using time (%))
27401 6-30060 GB
(**) IMPORTANT: if the machine has been filled with biodegradable hydraulic oil PANOLIN AG.-HLP SYNTH 46 (opt), be informed that this oil cannot be mixed with mineral hydraulic oil. Carefully follow the use indications detailed in the section VARIANTS of this manual. In case of doubts, refer to the dealer.
Filter element change interval
Hydraulic oil change interval
Change intervals (hrs)
Study SAFETY RULES in the front of this manual thoroughly for the protection of machine and safety of personnel
231