The Reset Fast Adapt window contains 10 tabs; one for each shift that can reset adaptive shift parameters. The following information displays in the Reset Adaptive Shift Parameters window: Item Name The name of a parameter. Value The numerical value of the parameter. Units Unit Of Measure for the parameter value—cc (cubic centimeter), kPa (kilopascal), sec (second). The adaptive shift parameters are reset when you click on the RESET SHIFT ADAPTIVE PARAMETERS button—the Reset Shift Adaptive Parameters Successful window displays. Click the OK button.
1000/2000 Throttle Calibration Throttle Calibration re-initializes the values of throttle sensor input that indicates closed throttle and full (wide open) throttle. Reset throttle calibration if the throttle sensor experienced over-travel or under-travel outside of normal operational limits and within failure limits. The resetting action does not have any effect on throttle information when such signal is received via J1939 or any other digital communication link.