Tadano Faun AML-LIIB Overload Prevention Device Service Manual W301-0212E - PDF DOWNLOAD

Page 78

Functions of and How to Use User Mode (GR-700EXL-1) (1) is applicable when the outriggers are extended to maximum 7.2m. (2) is applicable when the outriggers are extended to middle 6.7m. (3) is applicable when the outriggers are extended to middle 5.5m. [NOTICE] In the above table, "Buzzer" is the device outside the AML unit, outputting buzzing sound. "AML buzzer" is the device inside the AML unit, outputting beeping sound. The AML buzzer sounds for 3 seconds every time a message appears. It outputs long sounds when slow stop control is activated and outputs short sounds when other controls are activated.

77

W301-0212E


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.
Tadano Faun AML-LIIB Overload Prevention Device Service Manual W301-0212E - PDF DOWNLOAD by www.heydownloads.com - Issuu