Lift mast – 7000 Main mast T-code 795
Valid from serial number 904526-
Date 2006-04-10
Order number 235568-040
12.1.2 Maintenance 8
Mounting The maintenance schedule states that only a visual inspection of the mast mounting bolts (8) must be carried out and that they must not be tightened when they are checked. If the mast has to be replaced or if the bolts have become loose, new bolts and washers must be used. The tightening torque must be 150+/-15 Nm.
Lubrication Lubricating the beam 1 Fig. 18 Bolt joints
2
12- 2
The inner sides of the beam flanges must be lubricated with part no. 223690 (Q8 Rembrandt EP2).
1
2
The inner sides of the beam rib must be lubricated with part no. 29586 (Gleitmo 805).
Service Manual
SP10, SP10S
© TIEE SARL