1 minute read
Electrical system – 5000
Diagnostic and troubleshooting
T-codeValid from serial numberDateOrder number 795904526-2006-04-10235568-040
Table 15: List of error codes
¤¤¤ ¤ (3+1) TH. PROTECTION
Working temperature of transistor regulator is abnormally high or low (outside range >70°C or <10°C). Transistor regulator defect. / First determine whether truck’s operating environment and conditions are normal! Allow truck to regain a normal temperature and attempt normal use. If fault persists replace transistor regulator.
¤¤¤ ¤¤¤ (3+3) VACC NOT OK
Problem with speed potentiometer[R1].
[L1] not in neutral position when truck switched on. Fault in potentiometer wiring or in potentiometer. Incorrect calibration values. / Check wiring to potentiometer. Check and if necessary replace potentiometer. If necessary calibrate potentiometer. See “10.10.6 Calibrating the speed potentiometer” on page 38. ¤¤¤ ¤¤¤¤¤ (3+5) INCORRECT START
Starting sequence incorrect for travel. Emergency reverse switch [S20] operated during start. o/c in main contactor coil circuit [K10]. Tiller switch [S10] operated during start. / Check wiring to [S10] & [S20]. Adjust or replace these switches. Check wiring to [K10] coil & check or replace[K10].
Conflicting travel direction order. / Check wiring to [S15] & [S16], check operation of [S15] & [S16]. ¤¤¤
FORW+BACK
(3+7) BELLY SW ERROR
CHECK UP NEEDED
No connection to emergency reverse switch [S20]. / Check wiring to [S20], Check 3K3 resistor.
A scheduled service is due!
Time since last service > CHECK UP HOURS. The service counter may not have been reset following the previous service visit. / Establish service requirements and situation. Perform the scheduled service and reset service counter as appropriate.
See Reset service counter (CHECK UP DONE) on page 35.
¤.............¤ 32 short BATTERY LOW Battery charge less than 50% of nominal value. / Charge batteries.