1 minute read

Electrical system – 5000

Parameters & adjustments

Value 3 - Warning given when service counter has reached CHECK UP HOURS value. After 10 hours continued operation the maximum speed will be reduced. After 20 hours continued operation all truck operation will be blocked.

The warning for “time for service” is:

•An audible alarm signal from the transistor regulator.

•The status LED on the transistor regulator will flash 3 short + 8 long.

•The battery charge status [H81] LED flashes continuously.

“Time to next service” (CHECK UP HOURS)

Set this value to correspond with number of hours truck activity must increase by when the next service warning must be given.

Time to next service = 200 + (p X 50) hours, where p = parameter value.

10.10.5 Transferring parameter sets General

The Hand terminal can be used to save a parameter set and configuration from a truck. This is useful in the following cases:

•To restore a truck’s configuration to a known state or after replacing the transistor regulator.

•To transfer the configuration from one truck which has been configured to a complete group thus ensuring all trucks are identically configured.

The hand terminal can store up to a maximum of 32 unique parameter sets.

Electrical system – 5000

Parameters & adjustments

From the truck to the hand terminal

To transfer a parameter set from the truck to the hand terminal use the PARAMETER CHANGE function in the hand terminal:

•Connect the hand terminal. See “ Connecting the hand terminal” on page 23

SEM-XV.. 24v75A00000

*MAINMENU*

PARAMETERCHANGE

*MAINMENU*

STEERTABLE

*MAINMENU*

PROGRAMVACC

*MAINMENU* ALARMS

*MAINMENU* RESTORPARAM.

*MAINMENU* SAVEPARAM.

•Select SAVE PARAM from the menu and press ENTER.

•Press ROLL to select one of the 32 memory slots (Mod 00 to Mod 31).

Empty memory slots will display FREE. Memory slots which contain a parameter set will display SEM-X V.

•Press ENTER to save the truck’s parameter set.

NOTE!

It is advisable to keep a record of trucks and stored parameter sets. This will help to ensure that saved parameter sets are restored to the correct truck.