1 minute read

Electrical system – 5000

Next Article
Lift mast – 7000

Lift mast – 7000

10.8.5 Speed limitation

The truck's maximum travel speed is limited depending on a combination of factors:

•Load and remaining battery capacity.

•Whether the lift function is operating.

•The transistor regulator temperature.

•Extended use after service warning.

•Parameter settings also affect maximum speed.

See List of parameters on page 34 for more information. The table below summarises the speed limitations and assumes that all relevant parameters are set to 100%. Note that the speeds given are nominal. When a combination of limiting factors are present the lowest speed will be active.

Table 14: Summary of speed limitations

a.Dependant on parameter settings. See Select service warning type (CHECK UP TYPE) on page 35.

b.Dependant on parameter settings. See Select service warning type (CHECK UP TYPE) on page 35.

10.8.6 Hour meter

The truck’s control system stores the elapsed activity time (drive motor) in units of hours. A “time to next service” counter can optionally be activated. When this service counter time reaches the “time to next service” value the transistor regulator emits an audible signal and the Battery charge status [H81] LED flashes continuously.

To check the present activity time value connect the hand terminal. The activity time is displayed as shown in Fig. 13 “H”