Electrical system – 5000
Parameters & adjustments
•If the response of the speed control is not balanced in both travel directions.
•If the VACC NOT OK error occurs.
•When [R1] is removed or disturbed or is replaced.
Procedure
To perform calibration of the speed potentiometer use the PROGRAM VACC function in the hand terminal:
•Connect the hand terminal. See “ Connecting the hand terminal” on page 23.
YES=ENTERNO=OUT
•Select PROGRAM VACC from the menu and press ENTER then ENTER.
•Move tiller arm to drive position.
•Slowly move the speed control [L1] from neutral to full deflection first in one direction then the other direction.
•Press OUT followed by ENTER.
The transistor regulator and potentiometer have now been calibrated.