Hydraulic system - 6000 Description T-code 795
Valid from serial number 904526-
Date 2006-04-10
Order number 235568-040
11.3 Description Lift The lifting motion occurs when the pump motor (M3) is run. Lift speed depends on load weight. The non-return valve prevents leakage through the pump. When the load is in the lifted position, it is held in place by the non-return valve and the closed electric lowering valve (Y41).
Lower By opening the electric lowering valve (Y41), the load is lowered and the maximum lowering speed of the forks is regulated by the flow control valve. A pressure limit valve (overflow valve) prevents overload and protects the pump motor from overpressure. A hose rupture valve is located at the cylinder to prevent the load from falling uncontrollably in the event of a hose rupturing.
Operating pressure Operating pressure at rated load is 190 bar.
Pressure limit valve The pressure limit valve opens at 210 bar.
11- 4
Service Manual
SP10, SP10S
© TIEE SARL