Electrical system – 5000 Parameters & adjustments Order number 235568-040

Date 2006-04-10

Valid from serial number 904526-

T-code 795

• If the response of the speed control is not balanced in both travel directions. • If the VACC NOT OK error occurs. • When [R1] is removed or disturbed or is replaced.

Procedure To perform calibration of the speed potentiometer use the PROGRAM VACC function in the hand terminal: • Connect the hand terminal. See “ Connecting the hand terminal” on page 23. SEM-X 24v

75A

V.. 00000

ENTER * ROLL

* *

MAIN MENU * PARAMETER CHANGE MAIN MENU * STEER TABLE MAIN MENU * PROGRAM VACC

ENTER

VACC SETTING

ENTER

0.4

4.7 OUT

MIN 0.0

VACC -

MAX 0.0 Slowly move the speed control towards max in both directions

MIN 0.5

VACC

MAX 4.8

OUT

ARE YOU SURE ?

OUT

YES = ENTER NO = OUT ENTER

• Select PROGRAM VACC from the menu and press ENTER then ENTER. • Move tiller arm to drive position. • Slowly move the speed control [L1] from neutral to full deflection first in one direction then the other direction. • Press OUT followed by ENTER. The transistor regulator and potentiometer have now been calibrated. © TIEE SARL

Service Manual

SP10, SP10S

10- 39