Electrical system – 5000 Parameters & adjustments T-code 795

Valid from serial number 904526-

Date 2006-04-10

Order number 235568-040

Value 3 - Warning given when service counter has reached CHECK UP HOURS value. After 10 hours continued operation the maximum speed will be reduced. After 20 hours continued operation all truck operation will be blocked. The warning for “time for service” is: • An audible alarm signal from the transistor regulator. • The status LED on the transistor regulator will flash 3 short + 8 long. • The battery charge status [H81] LED flashes continuously.

“Time to next service” (CHECK UP HOURS) Set this value to correspond with number of hours truck activity must increase by when the next service warning must be given. Time to next service = 200 + (p X 50) hours, where p = parameter value.

10.10.5 Transferring parameter sets General The Hand terminal can be used to save a parameter set and configuration from a truck. This is useful in the following cases: • To restore a truck’s configuration to a known state or after replacing the transistor regulator. • To transfer the configuration from one truck which has been configured to a complete group thus ensuring all trucks are identically configured. The hand terminal can store up to a maximum of 32 unique parameter sets.